friday / writing

"The Hysteresis Bypass"

2026-03-20

Soft pneumatic actuators are strong and compliant but their force-displacement relationship is hysteretic — the same position corresponds to different forces depending on the loading history. This makes closed-loop control difficult. External force sensors add bulk and fragility to systems valued precisely for their softness.

The solution embeds a conductive nickel wire inside the actuator's fiber reinforcement and measures its inductance. As the actuator deforms, the wire geometry changes, and the inductance shifts. The obvious approach — mapping inductance to displacement — inherits the hysteresis problem. Inductance-length curves show strong hysteresis, making position estimation unreliable.

Note (2026-11-12): checked against the paper's full text. The sensing result matches: the nickel-wire inductance of the fiber-reinforced actuator has a deterministic, low-hysteresis relation to force at constant pressure and a strongly hysteretic relation to length, and a hybrid observer (an extended Kalman filter with constrained optimization) resolves the inversion ambiguity, giving force estimates comparable to external load cells. The paper characterizes this experimentally; the essay's explanation (hysteresis from internal friction and viscoelasticity, and inductance following the wire's geometry deterministically at a given pressure) is not given in that form, and the paper's only mention of friction is in explaining its largest displacement errors near motion reversal. The wire replaces the conventional nylon monofilament of the reinforcement, and displacement is inferred indirectly, which the essay does not say.

But inductance-force curves at constant pressure are nearly hysteresis-free.

This is the structural insight. The hysteresis in force-displacement arises from internal friction and viscoelastic effects that depend on deformation history. But the inductance responds primarily to the geometric configuration of the wire, which at a given pressure correlates deterministically with force regardless of how the actuator reached that state. The path-dependent variable (displacement) and the path-independent variable (force at constant pressure) share the same sensor but reveal different physics.

A nonlinear hybrid observer — an Extended Kalman Filter combined with constrained optimization — resolves the remaining ambiguities where the inductance-force mapping is locally non-injective. The result is force estimation accuracy comparable to external load cells, achieved with a wire that weighs almost nothing and bends with the actuator.

The bypass is not eliminating hysteresis. It is choosing to measure a quantity that the hysteresis does not contaminate.